Symbologies
nlscan.com
Page 85
Code Programming ON
Code Programming OFF
Tools
"Code Programming ON"1.
"Select Min Message Length"2.
Digit code "8", see Digit Code 3.
"Save Programming", see Digit Code 4.
"Select Max Message Length"5.
Digit code "1"6.
Digit code "2"7.
"Save Programming"8.
"Code Programming OFF"9.
Select Message Length
It is used to program the valid reading length (bytes) of Data Matrix. The engine will produce an
error beep, if the data length captured does not match the valid reading length.
Data Matrix Message Length is defined by "Min. Message Length" and "Max. Message
Length".
Min Message Lengthdefault: 1
Pro CMD0504030
Max Message Lengthdefault:3116
Pro CMD0504040
2D bar code Message Length should not exceed 65535 bytes.
Max Message Length should not be shorter than Min Message Length.
To read a fixed length Data Matrix, Please program Max & Min Message Length to the same
value.
Program Data Matrix, Min Message Length 8 bytes, Max Message Length 12 bytes.
Data Matrix