Newland FM208 Guía de usuario Pagina 64

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 114
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 63
nlscan.com
Page 59
Symbologies
Code Programming ON
Code Programming OFF
Tools
Interleaved 2 of 5
Fixed Length Selection
Program the engine to read fixed length or fixed length area Interleaved 2 of 5. Command
programming use 3 decimal digits to define length value. The fixed length value MUST be 2 to 64
even value (32 even values).
When enabled, Interleaved 2 of 5 Selection prevail Message Length Selection
** Disable Fixed Length Selection
Pro CMD0405140
Select Code Length
Pro CMD0405160
Enable Fixed Length Selection
Pro CMD0405150
Undo Code Length Selection
Pro CMD0405170
The engine only read Interleaved 2 of 5 which are 12 and 24 bytes.
1. Code Programming ON, then Select Code Length
2. Digit Code 012
3. Save Programming
4. Digit Code 024
5. Save Programming, then Code Programming OFF
The engine only read Interleaved 2 of 5 between 12 bytes and 24 bytes.
1. Code Programming ON, then Select Code Length
2. Digit Code 012then read 024
3. Save Programming, then Code Programming OFF
Undo fixed length selections between 2 bytes and 64 bytes.
1. Code Programming ON, then Undo Code Length Selection
2. Digit Code 002, then read 064
3. Save Programming, then Code Programming OFF