Symbologies
nlscan.com
Page 71
Code Programming ON
Code Programming OFF
Tools
Read "Check, Transmit NO Check", only transmit barcode message. If barcode message length is
less than Min Message Length, this will lead to error beep.
E.g.Read a 4 bytes (include Check Byte) Codabar. Select Min Message Length to 4 bytes and
transmit NO Check byte. This leads to error beep.
** NO Check, Transmit All
Pro CMD0409050
Check, Transmit NO Check
Pro CMD0409060
Check, Transmit All
Pro CMD0409070
Check Byte
Codabar may include Check Byte (not compulsory) following its barcode message. Check Byte is
used to verify the barcode message.
"NO Check, Transmit All" enables to read without check and transmit all digits including barcode
message and Check Byte.
"Check, Transmit NO Check" enables to read and check. If verification is successful, transmit
barcode message; if not, Imager produce an error beep.
"Check, Transmit All" enables to read and check. If verification is successful, transmit all
messages; if not, Imager produces an error beep.
Codabar