Symbologies
nlscan.com
Page 44
Code Programming ON
Code Programming OFF
Tools
"Code Programming ON"1.
"Select Min Message Length"2.
Digit code "8", see Digit Code 3.
"Save Programming", see Digit Code 4.
"Select Max Message Length"5.
Digit code "1"6.
Digit code "2"7.
"Save Programming"8.
"Code Programming OFF"9.
Program Code 128, Min Message Length 8 bytes, Max Message Length 12 bytes.
1D bar code Message Length should not exceed 127 bytes.
Max Message Length should not be shorter than Min Message Length.
To read a fixed length Code 128, Please program Max & Min Message Length to the same value.
Min Message Length (default: 1)
Pro CMD0400030
Max Message Length (default: 48)
Pro CMD0400040
Select Message Length
It is used to program the valid reading length (bytes) of Code 128. The engine will produce an
error beep, if the data length captured does not match the valid reading length.
Code 128 Message Length is defined by "Min. Message Length" and "Max. Message Length".