Code Programming ON
Code Programming OFF
Tools
"Code Programming ON"1.
"Select Min Message Length"2.
Digit code "8", see Digit Code 3.
"Save Programming", see Digit Code 4.
"Select Max Message Length"5.
Digit code "1"6.
Digit code "2"7.
"Save Programming"8.
"Code Programming OFF"9.
Program Interleaved 2 of 5, Min Message Length 8 bytes, Max Message Length 12 bytes.
1D bar code Message Length should not exceed 127 bytes.
Max Message Length should not be shorter than Min Message Length.
To read a fixed length Interleaved 2 of 5, Please program Max & Min Message Length to the same
value.
Min Message Lengthdefault:4
Pro CMD
0405030
Max Message Lengthdefault:80
Pro CMD0405040
Select Message Length
It is used to program the valid reading length (bytes) of Interleaved 2 of 5. The engine will
produce an error beep, if the data length captured does not match the valid reading length.
Interleaved 2 of 5 Message Length is defined by "Min. Message Length" and "Max. Message
Length"