nlscan.com
Page 98
Prefix/Suffix
Code Programming ON
Code Programming OFF
Tools
Prohibit or Allow Stop Suffix
“Stop Suffix” is the termination for a string of barcode messages. It can not be
formatted like other suffix and prefix. It is fixed to the right and the very end of a barcode
transmission.
** Prohibit Stop Suffix
【Pro CMD:0309000】
Allow Stop Suffix
【Pro CMD:0309010】
Program Stop Suffix
Read “Program Stop Suffix”. Then program Stop Suffix in order by reading their hex respectively.
Note: The maximum length for Stop Suffix is 2 bytes.
Program Stop Suffix
【Pro CMD:0310000】
For Windows System, program stop suffix to be “new line character” (hex value 0x0D/0x0A)
1. Read “Code Programming ON”
2. Read “Program Stop Suffix”
3. Read “0”, “D”, “0”, “A”, in order
4. Read “Save Programming”
5. Read “Code Programming OFF”.
6. Read “Allow Stop Suffix” to enable “new line character” function.
Stop Prefix