Newland EM1300 Manual Pagina 120

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 136
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 119
nlscan.com
Page 111
Symbols
Tools
Code Programming ON
Code Programming OFF
Select Message Length
It is used to program the valid reading length of Plessey. The engine will
send an error beep, if the decoded data length does not match the valid
length.
Plessey Message Length is dened by Min. Message Length and
Max. Message Length .
Plessey
1D bar code Message Length should not exceed 255 bytes. If Max Message Length is less
than Min Message Length, it means the engine will only support barcodes of the two lengths.
If Max Message Length is equal to Min Message Length, the engine will only support bar-
codes of the length.
To set Min Message Length of Plessey to 8 bytes and the Max Message Length to 12 bytes.
Read these programming code:
1. Code Programming ON
2. Select Min Message Length
3. Digit Code 8, see Digit Code (Appendix Pxxx)
4. Save Programming, see Digit Code (Appendix Pxxx)
5. Select Max Message Length
6. Digit Code 1
7. Digit Code 2
8. Save Programming
9. Code Programming OFF
Min Message Length
Pro CMD99913006
Max Message Length
Pro CMD99913007
Vista de pagina 119
1 2 ... 115 116 117 118 119 120 121 122 123 124 125 ... 135 136

Comentarios a estos manuales

Sin comentarios