Symbols
Code Programming ON
Code Programming OFF
Tools
PDF417
Select Message Length
It is used to program the valid reading length of PDF417. The engine will not send
barcode message to the Host, if the decoded data length does not match the valid
reading length.
PDF417 Message Length is dened by "Min. Message Length" and "Max. Message
Length ".
2D bar code Message Length should not exceed 65535 bytes.
Max Message Length should not be less than Min Message Length.
To read a xed length PDF417, Please program Max & Min Message Length to the same
value.
To set Min Message Length of PDF417 to 8 bytes and Max Message Length to 12 bytes,
read these programming codes:
1. Code Programming ON
2. Select Min Message Length
3. Digit Code 8, see Digit Code
4. Save Programming,see Digit Code
5. SelectMax Message Length
6. Digit Code 1
7. Digit Code 2
8. Save Programming
9. Code Programming OFF
Min Message Length (default: 1)
Pro CMD0501030
Max Message Length (default: 2710)
Pro CMD0501040