nlscan.com
Page 106
Symbols
Tools
Code Programming ON
Code Programming OFF
Select Message Length
MSI-Plessey Message Length is defined by Min. Message Length and
Max. Message Length .It is used to program the valid reading length of
MSI-Plessey. The engine will send an error beep, if the decoded data length
does not match the valid length.
MSI-Plessey
1D bar code Message Length should not exceed 255 bytes. If Max Message Length is less
than Min Message Length, it means the engine will only support barcodes of the two lengths.
If Max Message Length is equal to Min Message Length, the engine will only support bar-
codes of the length.
To set Min Message Length of MSI-Plessey to 8 bytes and the Max Message Length to 12
bytes. Read these programming code:
1. Code Programming ON
2. Select Min Message Length
3. Digit Code 8, see Digit Code (Appendix Pxxx)
4. Save Programming, see Digit Code (Appendix Pxxx)
5. Select Max Message Length
6. Digit Code 1
7. Digit Code 2
8. Save Programming
9. Code Programming OFF
Min Message Length
Pro CMD99913111
Max Message Length
Pro CMD99913112